Learn to Brew
The brewer’s workbench
The brewer’s workbenchRefractometer Calculator
Convert unfermented wort readings, or estimate late-fermentation beer gravity with an alcohol correction.
How it is calculated
Before fermentation: B = raw Brix / wort correction factor. SG = 1 + B / [258.6 − (B / 258.2) × 227.1]. The SG-to-Brix mode uses the exact algebraic inverse. After fermentation: estimated FG = 1 − 0.00085683 × original corrected Brix + 0.0034941 × current corrected Brix (Terrill linear model). Original SG is converted to corrected Brix with the same inverse. The post-fermentation model is restricted here to beer with original corrected Brix 5–32 and estimated apparent attenuation at least 61%; it is not an early-fermentation monitor.
References & assumptions
- Sean Terrill: measured refractometer results
- Measuring your wort correction factor
- Brewers Friend: Brix conversion
Method documented October 2026. Estimates depend on measurement quality.
Tips & measurement guidance
- Alcohol changes refractive index. Do not interpret an uncorrected fermented sample as actual final gravity.
- Calibrate the instrument as its maker directs, allow the sample and prism to stabilize, and use a clean prism with the specified sample amount.
- 1.04 is a starting estimate for wort correction, not a universal instrument constant. Compare several unfermented wort samples with a calibrated hydrometer to establish your factor.
- Confirm final gravity with a hydrometer. This beer model is not validated here for wine, mead, cider or seltzer. Different empirical models can legitimately disagree.